Technical note: modified method for utilizing the Farabeuf clamp in pelvic and acetabulum fracture fixation, addressing common challenges associated with its application.

No Thumbnail Available

All Authors

Davidson, A.
Santolini, E.
Kanakaris, NK.

LTHT Author

Davidson, Amit
Santolini, Emmanuele
Kanakaris, Nikolaos

LTHT Department

Orthopaedics
Trauma & Related Services
Major Trauma Centre

Non Medic

Publication Date

2025

Item Type

Journal Article

Language

Subject

Subject Headings

Abstract

Pelvic fracture fixation poses significant challenges due to limited exposure of the fracture site and the interference of reduction instruments with optimal placement of fixation plates. The ideal anatomical position for plate fixation is often occupied by reduction clamps, complicating the surgical process-particularly when using the Farabeuf clamp. While the Farabeuf clamp is a common tool in pelvic fracture surgery, this technical note introduces a modified technique for its application. This approach allows for simultaneous fracture reduction and plate placement, effectively restructuring the fixation process into a single-step procedure.

Journal

European journal of orthopaedic surgery & traumatologie