Antimicrobial susceptibility testing of Clostridioides difficile: a dual-site study of three different media and three therapeutic antimicrobials.
No Thumbnail Available
All Authors
Freeman, J.
Sanders, IMJG.
Harmanus, C.
Clark, EV.
Berry, AM.
Smits, WK.
LTHT Author
Freeman, Jane
Clark, Anna
Clark, Anna
LTHT Department
NIHR Leeds Biomedical Research Centre
Oncology
Leeds Cancer Centre
Oncology
Leeds Cancer Centre
Non Medic
Clinical Scientist
Publication Date
2025
Item Type
Journal Article
Language
Subject
Subject Headings
Abstract
OBJECTIVES: Increasing resistance to antimicrobials used for the treatment of Clostridioides difficile infections necessitates reproducible antimicrobial susceptibility testing. Current guidelines take a one-size-fits-all approach and/or offer limited guidance. We investigated how the choice of medium affects measured MIC values across two sites.
METHODS: We determined MIC values for the antimicrobials fidaxomicin, metronidazole, and vancomycin for a representative collection of European C. difficile strains (n = 235) using agar dilution on three different media: Brucella Blood Agar (BBA), Fastidious Anaerobe Agar supplemented with horse blood (FAA-HB), and Wilkins-Chalgren (WC) agar. The study was conducted at two sites to compare reproducibility. Usability (ease of preparation of the media as well as read-out of the assay) was assessed through a survey.
RESULTS: We found that all media result in highly consistent aggregated MIC data for all antibiotics, with MIC50 and MIC90 within two-fold of each other across sites. For fidaxomin, MIC values on WC were lower than on the other media (MIC90: WC = 0.125-0.25 mg/L; BBA and FAA-HB = 0.5 mg/L). Metronidazole showed the lowest MIC on BBA and the highest on WC (MIC90: WC = 2 mg/L; BBA = 0.5-1 mg/L; FAA-HB: 1-2 mg/L). For vancomycin, MIC values were similar across media (MIC90: all media = 1-2 mg/L). Though absolute values for individual isolates differed between sites, identified resistant isolates were similar. Results obtained on FAA-HB were most consistent between sites and results obtained on WC showed the most divergence. FAA-HB was positively evaluated in the usability survey.
DISCUSSION: This study shows medium-dependent differences in C. difficile MICs for at least two antimicrobials across two sites. We suggest the use of FAA-HB to align with general European Committee on Antimicrobial Susceptibility Testing (EUCAST) recommendations for susceptibility testing of anaerobic bacteria and deposited reference strains for standard susceptibility testing of C. difficile to increase interlaboratory reproducibility.
Journal
Clinical Microbiology & Infection